1 | * IDEC MANUFACTURER'S REPRESENTATIVE: * | 2 | * HYLAND AUTOMATION CONTROLS, INC. * | 3 | * 111 SOUTH BEDFORD STREET - SUITE 108 * | 4 | * BURLINGTON, MA 01803-5145 * | 5 | * TEL: 781.229.5600 FAX: 781.229.5640 * | 6 | * CONTACTS: * | 7 | * JERRY HYLAND - PRESIDENT * | 8 | * http://www.HylandAutomation.com * | 9 | * email: jerry@hylandautomation.com * | 10 | * * | 11 | * IDEC LADDER LOGIC DOCUMENTATION SOFTWARE: * | 12 | * CLIP VERSION 6.0 * | 13 | * FILE: ONDELAYP * | 14 | * FILE DATE: SEPTEMBER 6, 1998 * | 15 | * * | 16 | * IDEC FA SERIES AND MICRO 1 PLC * | 17 | * * | 18 | * * | 19 | * ================================================ * | 20 | * PLC PROGRAM * | 21 | * ================================================ * | 22 | * * | 23 | * ON DELAY TIMER * | 24 | * THE IDEC FA FAMILY AND MICRO 1 TIMERS DEFAULT TO * | 25 | * AN ON DELAY TIMER. WHEN POWER FLOWS TO THE * | 26 | * TIMER COIL THE TIMER BEGINS TIMING. WHEN POWER * | 27 | * IS INTERRUPTED TO THE TIMER COIL IT RESETS BACK * | 28 | * TO ITS PRESET VALUE. * | 29 | * THE VALUE BELOW THE TIMER COIL NUMBER IS THE * | 30 | * TIMER'S PRESET IN 100 MILLISECOND OR TENTHS OF * | 31 | * SECONDS. A PRESET OF 50 IS 5.0 SECONDS. * | 32 | * * | | ON | |DELAY ON | |TRIGGR DELAY | |INPUT TIMER | 33 +--| |-----------------------------------------------------------[T 10]+ | I 1 50 | | | 34 | | | | | | 35 | * * | 36 | * PLC OUTPUT SECTION * | 37 | * * | 38 | * OUTPUT 200 ENERGIZES WHEN TIMER 10 TIMES OUT * | 39 | * * | | ON | | ON DELAY | |DELAY PLC | |TIMER OUTPUT | 40 +--| |------------------------------------------------------------( )+ | T 10 Q 0 | | |