1 | * IDEC MANUFACTURER'S REPRESENTATIVE: * | 2 | * HYLAND AUTOMATION CONTROLS, INC. * | 3 | * 111 SOUTH BEDFORD STREET - SUITE 108 * | 4 | * BURLINGTON, MA 01803-5145 * | 5 | * TEL: 781.229.5600 FAX: 781.229.5640 * | 6 | * CONTACTS: * | 7 | * JERRY HYLAND - PRESIDENT * | 8 | * http://www.HylandAutomation.com * | 9 | * email: jerry@hylandautomation.com * | 10 | * * | 11 | * IDEC LADDER LOGIC DOCUMENTATION SOFTWARE: * | 12 | * CLIP VERSION 6.0 * | 13 | * FILE: OFFDELYP * | 14 | * FILE DATE: SEPTEMBER 6, 1998 * | 15 | * * | 16 | * IDEC FA SERIES AND MICRO 1 PLC * | 17 | * * | 18 | * * | 19 | * ================================================ * | 20 | * PLC PROGRAM * | 21 | * ================================================ * | 22 | * * | 23 | * OFF DELAY TIMER * | 24 | * THE IDEC FA FAMILY AND MICRO 1 TIMERS DEFAULT TO * | 25 | * AN ON DELAY TIMER. WHEN POWER FLOWS TO THE * | 26 | * TIMER COIL THE TIMER BEGINS TIMING. WHEN POWER * | 27 | * IS INTERRUPTED TO THE TIMER COIL IT RESETS BACK * | 28 | * TO ITS PRESET VALUE. * | 29 | * AN OFF DELAY TIMER IS CREATED USING INTERNAL * | 30 | * RELAYS FROM THE PLC TO RETAIN THE INPUT SIGNAL * | 31 | * AFTER THE INPUT TURNS OFF. * | 32 | * I.R. 500 IS LATCHED ON WHEN INPUT 2 IS ON * | 33 | * * | | OFF INPUT | |DELAY OFF 2 ON | |CONTRL DELAY LATCH | |SIGNAL TIMER SIGNAL | 34 +--| |--+--|/|----------------------------------------------------( )+ | I 2 | T 11 M 100 | | | | |INPUT | | |2 ON | | |LATCH | | |SIGNAL | | 35 +--| |--+ | | M 100 | | | 36 | * * | 37 | * WHEN INPUT 2 GOES OFF AFTER BEING ON THEN I.R. * | 38 | * 501 IS LATCHED ON WHICH STARTS TIMER 11 TIMING. * | 39 | * * | | OFF INPUT INPUT | |DELAY 2 ON 2 OFF | |CONTRL LATCH LATCH | |SIGNAL SIGNAL SIGNAL | 40 +--|/|--+--| |----------------------------------------------------( )+ | I 2 | M 100 M 101 | | | | |INPUT | | |2 OFF | | |LATCH | | |SIGNAL | | 41 +--| |--+ | | M 101 | | | 42 | * * | 43 | * TIMER 11 BECOMES AN OFF DELAY TIMER BASED ON * | 44 | * THE CONTROL LOGIC FROM I.R. 500 AN 501. TIMER * | 45 | * 11 BEGINS TIMING WHEN INPUT 2 GOES OFF AFTER IT * | 46 | * WAS ON. WHEN THE TIMER TIMES OUT THE PLC * | 47 | * OUTPUT 201 WILL DEENERGIZE. * | 48 | * THE VALUE BELOW THE TIMER COIL NUMBER IS THE * | 49 | * TIMER'S PRESET IN 100 MILLISECOND OR TENTHS OF * | 50 | * SECONDS. A PRESET OF 75 IS 7.5 SECONDS. * | 51 | * * | |INPUT | |2 OFF OFF | |LATCH DELAY | |SIGNAL TIMER | 52 +--| |-----------------------------------------------------------[T 11]+ | M 101 75 | | | 53 | | | | | | 54 | * * | 55 | * PLC OUTPUT SECTION * | 56 | * * | 57 | * OUTPUT 201 ENERGIZES WHEN INPUT 2 GOES ON AND * | 58 | * STAYS ON WHEN INPUT 2 GOES OFF UNTIL THE PRESET * | 59 | * OF TIMER 11 IS REACHED. * | 60 | * * | |INPUT OFF | |2 ON DELAY | |LATCH PLC | |SIGNAL OUTPUT | 61 +--| |------------------------------------------------------------( )+ | M 100 Q 1 | | |